ISSN: 2168-9717

Tecnología de ingeniería arquitectónica

Acceso abierto

Nuestro grupo organiza más de 3000 Series de conferencias Eventos cada año en EE. UU., Europa y América. Asia con el apoyo de 1.000 sociedades científicas más y publica más de 700 Acceso abierto Revistas que contienen más de 50.000 personalidades eminentes, científicos de renombre como miembros del consejo editorial.

Revistas de acceso abierto que ganan más lectores y citas
700 revistas y 15 000 000 de lectores Cada revista obtiene más de 25 000 lectores

Indexado en
  • Índice Copérnico
  • Google Académico
  • sherpa romeo
  • Abrir puerta J
  • Revista GenámicaBuscar
  • Claves Académicas
  • Biblioteca de revistas electrónicas
  • Búsqueda de referencia
  • Universidad Hamdard
  • EBSCO AZ
  • OCLC-WorldCat
  • Catálogo en línea SWB
  • Biblioteca Virtual de Biología (vifabio)
  • publones
  • Pub Europeo
Comparte esta página

Abstracto

A Parametric Study of the Effect of Building Distributions and Size on the Propagation of Sound in the Urban Environment

Mostafa Refat A Ismail*

The net effect at a location deep in the urban fabric of noise arising from the operation of multiple distant sources can be expected to be a function of the building density and typical size of buildings in this area. However, little is known as to how these characteristics of the urban fabric affect noise propagation. In this paper sound propagation through a distributed array of medium sized simple building forms has been investigated, assuming that building faces produce perfect diffusion. The method adopted was to calculate the energy exchange between facades assuming hemispherical propagation from a point located at the centre of the illuminated area of a facade. Thus, the energy exchange between faces is replaced by arrays of point sources located on each face.

For the very regular street configuration employed in the model, it was found that there was a strong channelling effect when the source was located between facades lining a street.

The propagation of sound across a more irregular fabric configuration as a function of building density, building ground floor dimensions and building height was investigated. It was found that the sound attenuation rates for each configuration are linear and virtually identical at approximately 52dB per decade. However, for each configuration there are differences in levels at a particular location that can be attributed to the near field effect of local occlusion in the vicinity of the source. The similar attenuation rates suggest that after the initial occlusion effect has determined the amount of sound energy that progresses to the far field, the effect of occlusion for a higher building density is compensated for by reflections from the facades.