ISSN: 2168-9717

Tecnología de ingeniería arquitectónica

Acceso abierto

Nuestro grupo organiza más de 3000 Series de conferencias Eventos cada año en EE. UU., Europa y América. Asia con el apoyo de 1.000 sociedades científicas más y publica más de 700 Acceso abierto Revistas que contienen más de 50.000 personalidades eminentes, científicos de renombre como miembros del consejo editorial.

Revistas de acceso abierto que ganan más lectores y citas
700 revistas y 15 000 000 de lectores Cada revista obtiene más de 25 000 lectores

Indexado en
  • Índice Copérnico
  • Google Académico
  • sherpa romeo
  • Abrir puerta J
  • Revista GenámicaBuscar
  • Claves Académicas
  • Biblioteca de revistas electrónicas
  • Búsqueda de referencia
  • Universidad Hamdard
  • EBSCO AZ
  • OCLC-WorldCat
  • Catálogo en línea SWB
  • Biblioteca Virtual de Biología (vifabio)
  • publones
  • Pub Europeo
Comparte esta página

Abstracto

Analysis of the Use of Woody Biomass for Heating and Electricity

George Leo

This study analyses a regional biomass energy system in Japan. Herein, supported native characteristics, like the warmth load and distribution, we tend to compare the woody biomass used for warmth, electricity, and combined heat and power (CHP) with or while not a vicinity heating (DHS). During this study, target demands were selected from the particular residential and industrial sectors of Koriyama town in Fukushima Prefecture mistreatment 2 maps of warmth density. A heat pipe network between every buildings was designed mistreatment and also the quantity of woody biomass employed in every case was fastened specified it happy the warmth demands of heat-only boilers. Therefore, there have been no meshes with unit heat densities However, we tend to found areas with the specified heat densities and selected ninety buildings for the DHS. The case that each CHP and DHS was put in and also the CHP operational model followed the warmth demand was the foremost effective to scale back carbonic acid gas. Once individual heat-only boilers were put in in buildings, the carbonic acid gas reduction was substantial; but, the capital prices related to heat-only boilers were a lot of beyond the of the opposite situations. Once a heat-only boiler and DHS were put in the carbonic acid gas reduction was competitive with the “CHP follow” state of affairs, however, total price was costlier. what is more, reducing carbonic acid gas would be larger than that of “CHP follow” case notwithstanding the carbonic acid gas emissions issue of grid electricity was but 1/2 its current value.

Descargo de responsabilidad: este resumen se tradujo utilizando herramientas de inteligencia artificial y aún no ha sido revisado ni verificado.