ISSN: 2168-9717

Tecnología de ingeniería arquitectónica

Acceso abierto

Nuestro grupo organiza más de 3000 Series de conferencias Eventos cada año en EE. UU., Europa y América. Asia con el apoyo de 1.000 sociedades científicas más y publica más de 700 Acceso abierto Revistas que contienen más de 50.000 personalidades eminentes, científicos de renombre como miembros del consejo editorial.

Revistas de acceso abierto que ganan más lectores y citas
700 revistas y 15 000 000 de lectores Cada revista obtiene más de 25 000 lectores

Indexado en
  • Índice Copérnico
  • Google Académico
  • sherpa romeo
  • Abrir puerta J
  • Revista GenámicaBuscar
  • Claves Académicas
  • Biblioteca de revistas electrónicas
  • Búsqueda de referencia
  • Universidad Hamdard
  • EBSCO AZ
  • OCLC-WorldCat
  • Catálogo en línea SWB
  • Biblioteca Virtual de Biología (vifabio)
  • publones
  • Pub Europeo
Comparte esta página

Abstracto

Comparing the Daylight Performance of Windows in Contemporary and Tropical Modernist Buildings, in the Tropics, a Case Of Prempeh College, Kumasi, Ghana

Barbara Owusu Akosah

Objective: The study was aimed at identifying the factors that influence the choice of windows in residential buildings in general and contemporary and tropical modernist residential buildings specifically as well as comparing the window characteristics for daylighting such as windowsill height, room depth, head height, window size, that define a window as performing according to determine whether they were according to the required.

Method: The characteristics that define a window as performing according to required in contemporary and tropical modernist buildings (windowsill height, head height, room depth and window size) were measured. Windows in buildings for both cases were measured, and observation schedules were used to obtain data.

Results: Fenestrations in tropical modernist buildings were found to adhere to the standard with window size for maximum daylighting found within the range of 10% and 40% for all orientations. Southeast and southwest orientations allow for the penetration of maximum amount of light as compared to the other orientations. Windows in contemporary modernist building adhered to the standards except for the living room whose window head height was not as required. Windows in tropical modernist buildings spaces were according to the required.

Conclusion: Tropical modernist buildings were found to adhere to the standards as compared to contemporary buildings according to the parameters used in determining the daylight performance.