Nuestro grupo organiza más de 3000 Series de conferencias Eventos cada año en EE. UU., Europa y América. Asia con el apoyo de 1.000 sociedades científicas más y publica más de 700 Acceso abierto Revistas que contienen más de 50.000 personalidades eminentes, científicos de renombre como miembros del consejo editorial.

Revistas de acceso abierto que ganan más lectores y citas
700 revistas y 15 000 000 de lectores Cada revista obtiene más de 25 000 lectores

Indexado en
  • Índice Copérnico
  • Google Académico
  • Abrir puerta J
  • Revista GenámicaBuscar
  • InvestigaciónBiblia
  • Biblioteca de revistas electrónicas
  • Búsqueda de referencia
  • Universidad Hamdard
  • EBSCO AZ
  • OCLC-WorldCat
  • Catálogo en línea SWB
  • Biblioteca Virtual de Biología (vifabio)
  • publones
  • Fundación de Ginebra para la educación y la investigación médicas
  • ICMJE
Comparte esta página

Abstracto

CT scanning protocol in washin/washout method to reduce the effect of xenoninduced flow activation on xenon-enhanced computed tomography calculations: cerebral blood flow and partition coefficient

Shigeru Sase, Hideharu Nakano and Mitsuru Honda

Background: It has been required to reduce the effect of xenon-induced flow activation (Xe activation) in xenonenhanced computed tomography (Xe-CT). The goal of this work was to propose a CT scanning protocol in the washin/washout method that could reduce the Xe-activation effect on calculated cerebral blood flow (CBF) and partition coefficient (lambda) in Xe-CT.

Methods: In the 4-min washin/4-min washout protocol with 1-min interval scans, the effect of Xe activation was calculated by theoretical simulations under the following scanning protocols based on the reported transcranial Doppler measurements: A: 1-min intervals, B: skip scans during the first 2 min in washout, and C: no scan in washout. For ten healthy subjects, CBF and lambda for the cortical regions of the right and left middle cerebral artery (MCA) territories were evaluated in protocols A and B.

Results: Due to Xe activation, simulated CBF for gray matter was changed by 13%, 7% and 6%; simulated lambda for gray matter was changed by 2%, 4% and 4%; simulated CBF for white matter was changed by 11%, 10% and -1%; and simulated lambda for white matter was changed by 14%, 14% and 133% in protocols A, B and C, respectively. For the ten subjects, the mean differences between protocols A and B in obtained CBF were 1.85 (P=0.0337) and 2.23 mL/100g/min (P=0.0077), and those in obtained lambda were -0.042 (P<0.0001) and -0.041 (P<0.0001) for the right and left MCA territories respectively. This demonstrated that gray matter CBF by protocol A was statistically larger than that by protocol B, and gray matter lambda by protocol A was statistically smaller than that by protocol B, which agreed with the theoretical simulation results.

Descargo de responsabilidad: este resumen se tradujo utilizando herramientas de inteligencia artificial y aún no ha sido revisado ni verificado.