Nuestro grupo organiza más de 3000 Series de conferencias Eventos cada año en EE. UU., Europa y América. Asia con el apoyo de 1.000 sociedades científicas más y publica más de 700 Acceso abierto Revistas que contienen más de 50.000 personalidades eminentes, científicos de renombre como miembros del consejo editorial.

Revistas de acceso abierto que ganan más lectores y citas
700 revistas y 15 000 000 de lectores Cada revista obtiene más de 25 000 lectores

Indexado en
  • Índice Copérnico
  • Google Académico
  • Abrir puerta J
  • Claves Académicas
  • Infraestructura Nacional del Conocimiento de China (CNKI)
  • Búsqueda de referencia
  • Universidad Hamdard
  • EBSCO AZ
  • OCLC-WorldCat
  • publones
  • Fundación de Ginebra para la educación y la investigación médicas
  • Pub Europeo
  • Fundación de Ginebra para la educación e investigación médicas
  • ICMJE
Comparte esta página

Abstracto

Effect of Manual Force on Lumbar Side Bending Range of Motion

Tomonori Sato

Objective: We evaluated the immediate changes in intervertebral motion after application of lumbar manual force.

Methods: Fifteen male volunteers (aged 26–43 years) with no history of significant low back pain were recruited to participate as a study group (manual traction). Control group (without manual traction) consisted of fifteen male volunteers who are matched with age (age 21-45 years). Consenting volunteers were referred for three radiographs (neutral position, right side bending position prior to manual force and right side bending position after manual force). The L3/4 segment was chosen for manual force, which was performed by a single examiner. Frontal angular rotation of each lumbar spine segment and total lumbar spinal motion were measured radio graphically before and after manual force by a single investigator (radiologist). Within-group differences were assessed with the paired t test.

Results: Analysis of the pre-and post-manual force radiographs showed a significant average increase at the L3/4 segment from 4.9° to 6.4° and an improvement in the total range of motion from 17.8° to 19.5° in the study group. No significant increase was found at the L1/2, L2/3, or L4/5 segments in the study group. In the control group, there were no significant changes in all measurements.

Conclusion: These results suggest that manual force targeting the L3/4 segment results in an immediate increase in the angular motion of the L3/4 segment and improvement in total motion of the lumbar spine.

Descargo de responsabilidad: este resumen se tradujo utilizando herramientas de inteligencia artificial y aún no ha sido revisado ni verificado.